JASO D611 STANDARD PDF

Automotive Cables to ISO, SAEJ, JASO D Automotive Cables. APPLICATIONS OVERVIEW. Standard wall automotive cables are ideal for use in. AVSS Automotive Wire JASO D Construction (No./mm), calculated area ( mm2), Outer Diameter (mm), Standard (mm), Min. (mm), Standard (mm), Max. AVSS Japanese Standard Automotive Cable Conductor:Cu-ETP1 bare according to JIS Insulation:PVC Standard Compliance:JASO D

Author: Kagashakar Jushura
Country: Laos
Language: English (Spanish)
Genre: Software
Published (Last): 8 May 2008
Pages: 153
PDF File Size: 3.67 Mb
ePub File Size: 8.44 Mb
ISBN: 823-1-46641-356-4
Downloads: 23465
Price: Free* [*Free Regsitration Required]
Uploader: Zubei

However, the conductor material for nominal size 0. For this reason, the current details are applied unchanged. Matters related to patent rights This standard includes no matters related to patent rights. In addition, this standard does not specify indication of the rated voltage on the cable itself or packaging.

Minimum number of abrasion cycles shall be as specified in Table Test method detail item 6. For other fuels, the test shall be performed upon an agreement between the parties involved in delivery. The impact test shall be conducted in accordance with the method specified in 5. The burning cable shall self extinguish within 30 seconds after exposure to naked flame.

Therefore, no wire diameter is specified in the construction table and only “circular compression” is described. The nominal size includes the “f” type. The tape abrasion test shall be conducted stajdard accordance with the method specified in 5. Packaging Products shall be packaged either on a reel or in bundle, and such that they are not easily damaged during transportation.

  ANASTREPHA SUSPENSA PDF

As required, the most recently updated version of the applicable standard including addenda shall be applied. In addition, the cables conforming to ISO in this revision are as follows: In addition, some nominal sizes include “f”, and the note “The symbol ‘f’ in the ‘Nominal size’ column means Explanatory notes 2 The organization and integration of types and symbols require sgandard understanding and cooperation of many relevant people, and a temporary increase in the types and staneard in These shall be organized and integrated at the next regular review of the 0.

This test is applicable to the nominal sizes of 5 or less. The insulation ator shall not be fractured in the voltage resistance test in 6.

When the rate of outside diameter changer is measured after the specified test and subsequently the winding test in 6. Standarx of specified items in specified elements 5. The insulation shall not be fractured in the specified test.

The idea was not adopted because those indications are not made worldwide and because of a problem related to manufacturing equipment difficulty of application to extremely thin cables. Jasl conductor extremely thin wall halogen-free insulated low-voltage cables for automobiles CAVUS: Therefore, cables of different classes cannot be integrated simply as a single type, and are used separately.

Conductor Calculated Nominal Number of Approx. Inthe standard was revised to include these cables. Performance Cable performance shall be as specified in Tables 2 to 7. The insulation shall not be fractured in the voltage resistance test in 6. Construction and material 5.

JASO De_图文_百度文库

The burning cable shall self extinguish within 15 seconds after exposure to naked flame. In addition, the necessity and method of voltage indication must be discussed to establish its future direction. Thin wall low-voltage cables for automobiles, type 2 HFSS: Initially, the international standard ISO for automotive cables also contained no specifications about rated voltage, but in the revision innew rated voltage classes of 60 V and Sandard were provided and their voltage resistance requirements were clearly specified considering the development of new 42 V automotive electric system and the expanding trend of electric vehicles.

  CONVERT FXM FILES TO PDF

Therefore, the horizontal burning test in the JASO standard was adopted. Xtandard and background of revision 1.

UL, Jaso D611 Standards AVS Type Automotive Wire

Especially for the short-term aging test, heat load test, and heat resistance test that are under revision deliberation in ISOit is important to insist on the Japanese position to facilitate standard conformance.

When marking is applied on the cable surface to ajso the type and nominal size of a cable, it shall not be easily erasable. For the insulation materials, polyvinyl chloride mixture, halogen-free mixture, cross-linked PVC mixture, heat resistant PVC mixture, and cross-linked polyethylene mixture are used depending on the heat resistance class, and have a different temperature rating.

These types and symbols must be organized and integrated in accordance with ISO standards in order to increase international competitiveness in the future.